Internal error (crc code - ram) [0x00690000, Internal error (logbook memory area) [0x00690001, Internal error (lds instance data) [0x00690002 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 455: 9400 highline | parameter setting & configuration

L
Firmware 1.37 - 09/2006
455
9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
Combination memory module/device not possible [0x0068001f]
Combination module in MXI1/device not possible [0x00680020]
Combination module in MXI2/device not possible [0x00680021]
Internal error (CRC code - RAM) [0x00690000]
Internal error (logbook memory area) [0x00690001]
Internal error (LDS instance data) [0x00690002]
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The memory module used is not supported by the
controller according to the license model.
Plug in supported module and switch the mains.
• Only memory module MM220 or MM330 may be
plugged in the 9400 HighLine.
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The extension module in the module receptacle MXI1 is
not supported by the controller.
• Remove the extension module and switch the mains.
• Plug in supported extension module and switch the
mains.
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The extension module in the module receptacle MXI2 is
not supported by the controller.
• Remove the extension module and switch the mains.
• Plug in supported extension module and switch the
mains.
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Serious device error or component failure.
Switch off and on controller.
• Please contact Lenze, if the problem occurs again.
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Serious device error or component failure.
Switch off and on controller.
• Please contact Lenze, if the problem occurs again.
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Serious device error or component failure.
Switch off and on controller.
• Please contact Lenze, if the problem occurs again.