3 system block "ls_quick stop, Block, Ls_quickstop – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 155: C 155), 9400 highline | parameter setting & configuration

L
Firmware 1.37 - 09/2006
155
9400 HighLine | Parameter setting & configuration
Basic drive functions
Quick stop | System block "LS_quick stop"
9.3.3
System block "LS_quick stop"
The LS_quick stop system block in the function block editor maps the basic function "Quick
stop".
Inputs
Outputs
Identifier
DIS code | data type
Information/possible settings
QSP_bActivate1
| BOOL
QSP_bActivate2
| BOOL
QSP_bActivate3
| BOOL
Activate quick stop
• The three inputs are linked via a logic OR gate.
TRUE If one of the three inputs is set to TRUE, it is changed to the function
state "Quick stop active" and the drive is braked to standstill within
the deceleration time set for quick stop.
TRUEÌFALSE When all three inputs are reset to FALSE, it is changed to a setpoint-
generating basic function (e.g. "speed follower") via the function
state "Drive is stopped".
Identifier
DIS code | data type
Value/meaning
QSP_bActive
| BOOL
Status output "quick stop is active"
TRUE Quick stop is active.
LS_Quickstop
QSP_bActivate1
QSP_bActive
STOP
n
t
³ 1
QSP_bActivate2
QSP_bActivate3