Read error - service register [0x00720000, External error [0x00750000, Controller is enabled [0x00750001 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 462: Controller has been initialised [0x00750002, Controller in sto state [0x00750003, Controller: pulse inhibit is active [0x00750005, 0x20750000, 9400 highline | parameter setting & configuration

9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
462
Firmware 1.37 - 09/2006
L
Read error - service register [0x00720000]
External error [0x00750000]
Controller is enabled [0x00750001]
Controller has been initialised [0x00750002]
Controller in STO state [0x00750003]
Controller: Pulse inhibit is active [0x00750005]
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
An error has occurred while reading or writing the service
register.
Mains switching
• Please contact Lenze, if the problem occurs again.
Response (Lenze setting printed in bold)
Setting:
(; Adjustable response)
;
None System fault : Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information
Cause
Remedy
The drive interface has activated the error message
"External error".
• The input DI_bSetExternError of the system block
LS_DriveInterface has been set to TRUE.
• Check external device to be monitored.
• Check assignment of the input DI_bSetExternError in
the application.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause
Remedy
The controller is enabled and has the "Operation" state. - (Information only)
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause
Remedy
The controller has left the "Initialisation active" state.
- (Information only)
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause
Remedy
The controller has received the "safe torque off" request
and is now in the "Safe Torque Off active" state.
- (Information only)
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause
Remedy
The pulse inhibit is active in the controller.
- (Information only)