Plc configuration is invalid [0x00750006, Heatsink: temperature > c00122 [0x00770000, Heatsink: overtemperature [0x00770001 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 463: Motor: temperature > c00121 [0x00770002, Motor: overtemperature [0x00770003, 9400 highline | parameter setting & configuration

L
Firmware 1.37 - 09/2006
463
9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
PLC configuration is invalid [0x00750006]
Heatsink: Temperature > C00122 [0x00770000]
Heatsink: Overtemperature [0x00770001]
Motor: Temperature > C00121 [0x00770002]
Motor: Overtemperature [0x00770003]
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
An invalid control configuration has occurred.
Load other application.
Response (Lenze setting printed in bold)
Setting:
(; Adjustable response)
;
None System fault ; Fault Trouble Quick stop by trouble Warning locked : Warning Information
Cause
Remedy
Heatsink temperature higher than variable limit
temperature (
).
• Controller ambient temperature too high.
• Dirty fan or ventilation slots.
• Value set under C00122 is too low.
• Check control cabinet temperature.
• Clean filter.
• Clean controller.
• Set a higher value under
.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Heatsink temperature higher than fixed limit
temperature (90 °C).
• Controller ambient temperature too high.
• Dirty fan or ventilation slots.
• Check control cabinet temperature.
• Clean filter.
• Clean controller.
Response (Lenze setting printed in bold)
Setting:
(; Adjustable response)
;
None System fault ; Fault Trouble Quick stop by trouble Warning locked : Warning Information
Cause
Remedy
Motor temperature higher than variable limit
temperature (
).
• Motor too hot due to impermissibly high currents or
frequent and too long acceleration.
• No PTC connected.
is too low.
• Check drive dimensioning.
• Connect PTC or switch off monitoring (
="3").
• Set a higher value under
.
Response (Lenze setting printed in bold)
Setting:
(; Adjustable response)
;
None System fault : Fault Trouble Quick stop by trouble Warning locked ; Warning Information
Cause
Remedy
Motor temperature higher than fixed limit temperature
(150 °C).
• Motor too hot due to impermissibly high currents or
frequent and too long acceleration.
• No PTC connected.
• Check drive dimensioning.
• Connect PTC or switch off monitoring (
="3").