C00579, C00580, C00581 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 588: 9400 highline | parameter setting & configuration

9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00579
588
Firmware 1.37 - 09/2006
L
C00579
C00580
C00581
Parameter | Name:
C00579 | Resp. to speed monitoring
Data type: UNSIGNED_32
Index: 23996
d
= 5DBC
h
Response to release of speed monitoring
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
;
Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00580 | Resp. to encoder open circuit
Data type: UNSIGNED_32
Index: 23995
d
= 5DBB
h
Response to open circuit in encoder
• For the use of the encoder as motor encoder: If an error occurs, the safe operation of the motor is no longer
ensured, therefore for safety reasons always the "Error" response should be set!
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
;
Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00581 | Resp. to external fault
Data type: UNSIGNED_32
Index: 23994
d
= 5DBA
h
Response to an external error
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
;
Read access ; Write access CINH PLC STOP No transfer COM MOT