C00270, C00271, C00272 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 566: C00273, C00274, C00270/1, C00270/2, C00271/1, C00271/2, C00272/1
![background image](/manuals/566320/566/background.png)
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00270
566
Firmware 1.37 - 09/2006
L
C00270
C00271
C00272
C00273
C00274
Parameter | Name:
C00270 | Freq. - current setpoint filter
Data type: UNSIGNED_32
Index: 24305
d
= 5EF1
h
Setting range
(min. value | unit | max. value)
1.0
Hz
1000.0
Subcodes
Lenze setting
Information
C00270/1
200.0 Hz
Freq. current setpoint filter 1
C00270/2
400.0 Hz
Freq. current setpoint filter 2
;
Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10
Parameter | Name:
C00271 | Width - current setpoint filter
Data type: UNSIGNED_32
Index: 24304
d
= 5EF0
h
Setting range
(min. value | unit | max. value)
0.0
Hz
500.0
Subcodes
Lenze setting
Information
C00271/1
20.0 Hz
Width current setp. filter 1
C00271/2
40.0 Hz
Width current setp. filter 2
;
Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10
Parameter | Name:
C00272 | Depth - current setpoint filter
Data type: UNSIGNED_32
Index: 24303
d
= 5EEF
h
With the setting "0 dB" the current setpoint filter is deactivated
Setting range
(min. value | unit | max. value)
0
db
100
Subcodes
Lenze setting
Information
C00272/1
0 db
Depth current setp. filter 1
C00272/2
0 db
Depth current setp. filter 2
;
Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00273 | Moment of inertia
Data type: UNSIGNED_32
Index: 24302
d
= 5EEE
h
Setting range
(min. value | unit | max. value)
0.00
kg cm²
10000.00
Subcodes
Lenze setting
Information
C00273/1
0.14 kg cm²
Motor moment of inertia
C00273/2
0.00 kg cm²
Load moment of inertia
;
Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00274 | Max. acceleration change
Data type: UNSIGNED_32
Index: 24301
d
= 5EED
h
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
%/ms
400.0 400.0 %/ms
;
Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10