C00586, C00587, C00588 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 590: C00589, 9400 highline | parameter setting & configuration
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00586
590
Firmware 1.37 - 09/2006
L
C00586
C00587
C00588
C00589
Parameter | Name:
C00586 | Resp. to resolver open circuit
Data type: UNSIGNED_32
Index: 23989
d
= 5DB5
h
Response to open circuit in resolver
• For the use of the resolver as motor encoder: If an error occurs, the safe operation of the motor is no longer
ensured, therefore for safety reasons always the "Error" response should be set!
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
;
Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00587 | Status - fan control
Data type: BITFIELD_8
Index: 23988
d
= 5DB4
h
Value is bit-coded:
Bit 0 Heatsink fan ON
Bit 1 Integral fan ON
Bit 2 Heatsink fan status 1
Bit 3 Heatsink fan status 2
Bit 4 Integral fan status
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00588 | Resp. to t. sensor drive failure
Data type: UNSIGNED_32
Index: 23987
d
= 5DB3
h
Response, to error/failure of temperature sensor for heatsink/temperature inside the controller
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
5 Warning
;
Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00589 | Resp. to CPU temp. > C00126
Data type: UNSIGNED_32
Index: 23986
d
= 5DB2
h
Response, if CPU temperature on the control card > variable limit temperature (
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
5 Warning
;
Read access ; Write access CINH PLC STOP No transfer COM MOT