C00005, C00006, C00007 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 547: C00011, C00018, C00019, The reference speed of the motor, Are required as speed setpoint, See the following table.), Ted in

L
Firmware 1.37 - 09/2006
547
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00005
C00005
C00006
C00007
C00011
C00018
C00019
Parameter | Name:
C00005 | Application selection
Data type: INTEGER_32
Index: 24570
d
= 5FFA
h
Application selection
• Use the controller command
="5" to activate the selected application.
Setting range
(min. value | unit | max. value)
Lenze setting
-1
16 0
;
Read access ; Write access CINH PLC STOP ; No transfer COM MOT
Parameter | Name:
C00006 | Motor control selection
Data type: UNSIGNED_32
Index: 24569
d
= 5FF9
h
Selection list
(Lenze setting printed in bold)
Information
1 Servo control with SM
For synchronous motors with speed sensor
2 Servo controller with ASM
For asynchronous motors with speed sensor
;
Read access ; Write access ; CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00007 | Active application
Data type: UNSIGNED_32
Index: 24568
d
= 5FF8
h
Display range
(min. value | unit | max. value)
0
4294967295
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00011 | Motor reference speed
Data type: UNSIGNED_32
Index: 24564
d
= 5FF4
h
For parameter setting via interface: In case of bigger changes, only change the setting in one step when the
controller is inhibited!
Setting range
(min. value | unit | max. value)
Lenze setting
50
rpm
50000 3000 rpm
;
Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00018 | Chopper frequency
Data type: UNSIGNED_32
Index: 24557
d
= 5FED
h
Selection list
(Lenze setting printed in bold)
Information
2 1 kHz fixed
Note:
The maximum output frequency of the controller is
limited to 1/8 of the switching frequency selected here!
3 2 kHz fixed
4 4 kHz fixed
5 8 kHz fixed
8 2 kHz variable
9 4 kHz variable
10 8 kHz variable
11 16 kHz variable
;
Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00019 | Zero speed detection threshold
Data type: UNSIGNED_32
Index: 24556
d
= 5FEC
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
rpm
450 5 rpm
;
Read access ; Write access CINH PLC STOP No transfer COM MOT