C01502, C01510, C01511 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 612: 9400 highline | parameter setting & configuration
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C01502
612
Firmware 1.37 - 09/2006
L
C01502
C01510
C01511
Parameter | Name:
C01502 | Resp. to comm. error with MXI2
Data type: UNSIGNED_32
Index: 23073
d
= 5A21
h
Response to communication error between "intelligent" module in module slot 2 and basic device
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
3 Quick stop by trouble
4 Warning locked
5 Warning
;
Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C01510 | Ethernet IP address client x
Data type: VISIBLE_STRING
Index: 23065
d
= 5A19
h
Display of the five possible server channels
• If a client is connected via one of these server channels, the IP address and the port of the client will be indicated
in the form of "xxx.xxx.xxx.xxx : yyyy".
• If no client is connected via the server channel, "---.---.---.--- : ----" will be indicated.
Subcodes
Information
C01510/1
Server channel 1 ... 5
C01510/...
C01510/5
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C01511 | Ethernet status client x
Data type: UNSIGNED_8
Index: 23064
d
= 5A18
h
Status of the five possible server channels
Selection list
0 Not connected
1 Connected
2 Stop
3 Unknown status
Subcodes
Information
C01511/1
Status of server channel 1 ... 5
C01511/...
C01511/5
;
Read access Write access CINH PLC STOP No transfer COM MOT