Oscilloscope
Operation
424
Firmware 1.37 - 09/2006
L
14.4.4
Starting recording
M
Click Start to start recording.
For obtaining a maximum sample rate when recording the variable values, the data is first
stored in the measured data memory of the controller and then transferred as a data
record to the PC.
r
The current recording status is displayed in the status bar.
14.4.5
Adjusting the representation
After the variable values have been recorded and the online data record has been
transferred to the PC, the data record is visualised in the oscillograph. If required, the
representation can now be adjusted by using the zoom or the automatic scaling function.
Zoom function
M
Go to the oscilloscope function bar and click the
icon to activate the zoom
function.
Zoom function
Procedure
Zoom selection
Hold down the left mouse button and draw the oscilloscope section to be
zoomed:
• The selection is shown with a frame.
• When the left mouse button is released, the selection is zoomed in the
oscilloscope.
Horizontal/vertical
shift of selection
Hold down the left and right mouse button and move the mouse pointer on the
horizontal scale to the left or right or on the vertical scale to the top or bottom
to shift the selection accordingly.
• With a three-button mouse, you can use the mouse button in the middle.
Horizontal stretching
Hold down the left mouse button and move the mouse pointer on the horizontal
scale to the left to stretch the shown selection from the right edge.
• Moving the mouse pointer in opposite direction continuously reduces the
stretching.
Hold down the right mouse button and move the mouse pointer on the
horizontal scale to the right to stretch the shown selection from the left edge.
• Moving the mouse pointer in opposite direction continuously reduces the
stretching.