Internal communication error (dma) [0x007b0034, Invalid plc configuration [0x007b0037, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 476

9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
476
Firmware 1.37 - 09/2006
L
Electronic nameplate: Unknown encoder signal [0x007b0033]
Internal communication error (DMA) [0x007b0034]
Internal communication error (MCTRL host) [0x007b0036]
Invalid PLC configuration [0x007b0037]
Motor parameter identification has been cancelled [0x007b0038]
Electronic nameplate: Data out of parameter limits [0x007b0039]
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause
Remedy
The connected motor with feedback is not supported by
the controller firmware.
Check drive dimensioning.
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Internal error.
Please contact Lenze.
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Internal error.
Please contact Lenze.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
An invalid control configuration has occurred.
Load other application.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The motor current during identification was too high.
• The motor must not move during identification.
• Check motor parameters
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning : Information
Cause
Remedy
The motor parameters of the electronic nameplate are
out of the limit values of the controller and therefore
cannot be accepted.
Please contact Lenze.