9400 HighLine | Parameter setting & configuration
Standard TAs
Introduction
242
Firmware 1.37 - 09/2006
L
11.1
Introduction
11.1.1
Application examples
Dosing drives
r
Both dosing drives are operated in speed-controlled mode and determine the mix ratio
with their speed:
[11-1] Example: Dosing drives with adjustable mix ratio v
1
/v
2
r
Technical connections/machine parameters:
n
Mains
o
System bus (CAN)
p
Drive 1 with TA "actuator – speed"
q
Drive 2 with TA "actuator – speed"
i = gearbox factor
n = Load reference speed in [rpm]
v = Reference speed in [m/s]
d = roll diameter in [m]
d
1
n
1
v
1
i
1
d
2
n
2
i
2
v
2
Parameters
Information
Motor reference speed
Gearbox fact. numer. motor
Gearbox fact. denom. motor
Load reference speed
Highlighted in grey = display parameter
Parameters
Information
Feed constant roll diameter in [m] * π
Selection of the unit [m]
Highlighted in grey = display parameter
Load reference speed [min-1] Motor reference speed [min-1]
Gearbox factor
-------------------------------------------------------------------------------
=
Reference speed [m/s] Roll diameter [m] π Load reference speed [min-1]
⋅ ⋅
60
-------------------------------------------------------------------------------------------------------------------------------------
=