Safety module has been removed [0x00680007, Control card is defective [0x00680008, Power section is defective [0x00680009 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 451: Mxi1: module is defective or missing [0x0068000a, Mxi2: module is defective or missing [0x0068000b, Memory module is defective or missing [0x0068000c, 9400 highline | parameter setting & configuration
L
Firmware 1.37 - 09/2006
451
9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
Safety module has been removed [0x00680007]
Control card is defective [0x00680008]
Power section is defective [0x00680009]
MXI1: Module is defective or missing [0x0068000a]
MXI2: Module is defective or missing [0x0068000b]
Memory module is defective or missing [0x0068000c]
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
You have tried to remove or change the safety module
during operation.
Switch off the controller, plug in safety module and
switch on the controller again.
• If the error occurs again, the safety module is
defective and must be replaced.
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Operating system could not identify the control card.
Please contact Lenze.
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Operating system could not identify the power stage.
Please contact Lenze.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Operating system could not identify extension module in
module receptacle MXI1.
• Use a different extension module.
• Please contact Lenze.
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Operating system could not identify extension module in
module receptacle MXI2.
• Use a different extension module.
• Please contact Lenze.
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Operating system could not identify the memory
module.
• Use a different memory module.
• Please contact Lenze.