7 "manual jog" mode, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 315
![background image](/manuals/566320/315/background.png)
L
Firmware 1.37 - 09/2006
315
9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Electronic gearbox" | "Manual jog" mode
12.2.7
"Manual jog" mode
In the "Manual jog" mode (C03006 = "4") the drive is decoupled from the electrical shaft
and the basic function "Manual jog" is enabled:
[12-18] "Manual jog" mode (schematic diagram)
r
Parameter setting: Tab Application parameter Dialog level Overview Manual jog
O
Tip!
Detailed information on the manual jog function can be found in chapter "Basic
drive functions" subchapter "
".
v
t
LS_ManualJog
n
t
и
з
n
t
LS_Positioner
0
-100
100 200
LS_Homing
C03006 = 4
t
M
Slave
Parameters
Lenze setting
Value Unit
Manual jog speed 1
360.0000 Unit/s
Manual jog speed 2
720.0000 Unit/s
Manual acceleration
360.0000 Unit/s
2
Manual deceleration
1440.0000 Unit/s
2
Inaccuracy time of manual traversing
0.100 s
C03007
Positive manual jog
Inactive
C03008
Negative manual jog
Inactive
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
C03007 Activate positive manual jog
C03155/2
C03008 Activate negative manual jog
C03155/3
FALSE Activate 2. speed
C03155/4
FALSE Retract limit switch
C03155/5