4 parameter attributes, The table footer contains the, Parameter attributes – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 542: 9400 highline | parameter setting & configuration
9400 HighLine | Parameter setting & configuration
Parameter reference
Structure of the parameter descriptions
542
Firmware 1.37 - 09/2006
L
16.1.4
Parameter attributes
Type of access
r
The first four attributes provide information about the parameter access:
Additional features
r
The following attributes refer to the parameter set transfer to the controller:
Scaling factor
r
The "scaling factor" is important for parameter access via bus systems. It is only
indicated for parameters using a data format with decimal positions:
Attribute
Meaning
;
Read access
Read access to parameter possible.
;
Write access
Write access to parameter possible.
• Please also observe the following attributes:
;
CINH
Parameter value can only be changed when the controller is
inhibited.
;
PLC STOP
Change of the parameter value is only possible when the application
is stopped.
Attribute
Meaning
;
No transfer
Parameter is not transferred to controller when the command Download parameter set is
executed.
;
COM
"PC communication parameter"
• In the Download parameter set or Download application dialog box, you can select that
PC communication parameters are not to be transferred to the controller.
;
MOT
"Motor data parameter"
• In the Download parameter set or Download application dialog box, you can select that
motor data parameters are not to be transferred to the controller.
Read value (via bus system)
Scaling factor indicated value (Engineer)
⋅
=