7 following error monitoring, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 400
![background image](/manuals/566320/400/background.png)
9400 HighLine | Parameter setting & configuration
TAs for positioning tasks
TA "Multi-purpose positioning" | Following error monitoring
400
Firmware 1.37 - 09/2006
L
13.2.7
Following error monitoring
[13-13] Following error monitoring
r
Parameter setting: Tab Application parameter Dialog level Overview Following
error
n
Switching threshold
o
Hysteresis
In the Lenze setting a two-stage following error monitoring is
active.
If the parameterisable switching threshold 1 is exceeded, a
warning appears. If the higher-set switching threshold 2 is
exceeded, a "warning locked" appears.
j
Parameters
Lenze setting
Value Unit
C03911
Switching threshold 1
100.0000 Unit
C03914
Switching threshold 2
200.0000 Unit
C03917
Hysteresis 1
0.0000 Unit
C03920
Hysteresis 2
0.0000 Unit
C05902/1
Error response - following error 1
Warning
C05902/2
Error response - following error 2
Warning locked
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
TRUE Activate following error limit 1
C03058/1
TRUE Activate following error limit 2
C03058/2