C00591, C00594, C00595 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 591: C00596, And select the error response required when, Default setting: "fault") is activated, C00591/1, C00591/2, C00591/3, C00591/4
![background image](/manuals/566320/591/background.png)
L
Firmware 1.37 - 09/2006
591
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00591
C00591
C00594
C00595
C00596
Parameter | Name:
C00591 | Resp. to CAN-RPDOx error
Data type: UNSIGNED_8
Index: 23984
d
= 5DB0
h
Response, if the corresponding CAN RPDO has not been received in the configured time or with the configured sync.
Selection list
0 No response
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
Subcodes
Lenze setting
Information
C00591/1
0: No response
Response to non received RPDO1 ... RPDO4
C00591/...
C00591/4
;
Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00594 | Resp. to t. sensor motor failure
Data type: UNSIGNED_32
Index: 23981
d
= 5DAD
h
Response to motor temperature sensor error.
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
5 Warning
;
Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00595 | Resp. to CAN bus off
Data type: UNSIGNED_8
Index: 23980
d
= 5DAC
h
Response, if CAN node switches to the bus off status.
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
;
Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00596 | Threshold max. speed reached
Data type: UNSIGNED_32
Index: 23979
d
= 5DAB
h
Threshold for speed monitoring
• The reaction for reaching the threshold can be selected in
Setting range
(min. value | unit | max. value)
Lenze setting
50
rpm
50000 6500 rpm
;
Read access ; Write access CINH PLC STOP No transfer COM MOT