1 function description, 2 filtering logbook entries, Filtering logbook entries – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 437: C 437), 9400 highline | parameter setting & configuration
L
Firmware 1.37 - 09/2006
437
9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Logbook
15.3.1
Function description
The structure of the logbook corresponds to a ring buffer structure:
[15-1] Ring buffer structure
15.3.2
Filtering logbook entries
Before the logbook logs new entries in the ring buffer, the entries are filtered by a
parameterisable filter.
This filter is used to exclude events with a certain error response (fault, warning,
information, etc.) from entry into the logbook.
r
The filter parameters are set under
[15-2] Bit mask for event-type filter
r
Example: Bit 6 must be set to "1" to exclude all events with "Information" response
from entry into the logbook:
[15-3] Example: Bit mask for hiding events with "Information" response
Current event
r
As long as free logbook memory capacity is
available, the entries will be saved at the next
free memory location.
r
If all memory locations are occupied, the oldest
entries will be deleted to save new entries.
n
n-1
n-2
0
Meaning:
System error
Information
Warning
Warning locked
Quick stop by trouble
Trouble
Fault
Not assigned
Bit 0
Bit 7
6
5
3 4
2
1
0
7
Meaning:
System error
Information
Warning
Warning locked
Quick stop by trouble
Trouble
Fault
Not assigned
Bit 0
Bit 7
1 0
0
0
0
0
0
6
5
3 4
2
1
0
7
0
Note!
Events with the set "None" response are not entered into the logbook.