C02580, C02581, C02582 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 625: C02583, C02585, The value at, Ed in, The brake activation is switched off, Has been selected in, Threshold set in
![background image](/manuals/566320/625/background.png)
L
Firmware 1.37 - 09/2006
625
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C02580
C02580
C02581
C02582
C02583
C02585
Parameter | Name:
C02580 | Brake operating mode
Data type: UNSIGNED_32
Index: 21995
d
= 55EB
h
Basic function "
Selection list
(Lenze setting printed in bold)
0 Brake control off
1 Directly with brake module
2 Autom. with brake module
11 Direct - external switching
12 Autom. - external switching
;
Read access ; Write access ; CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02581 | Brake activation threshold
Data type: INTEGER_32
Index: 21994
d
= 55EA
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0
rpm
50000 50 rpm
;
Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02582 | Brake resp. to pulse inhibit
Data type: UNSIGNED_32
Index: 21993
d
= 55E9
h
Basic function "
Selection list
(Lenze setting printed in bold)
0 Activate the brake immediately ; Read access ; Write access
CINH
PLC STOP
No transfer
COM
MOT Parameter | Name: C02583 | Status input monitoring Data type: UNSIGNED_32 Index: 21992 d = 55E8 h Basic function " Selection list (Lenze setting printed in bold) 0 Not active ; Read access ; Write access
CINH
PLC STOP
No transfer
COM
MOT Parameter | Name: C02585 | Brake control polarity Data type: UNSIGNED_32 Index: 21990 d = 55E6 h Basic function " Selection list (Lenze setting printed in bold) 0 Not inverted ; Read access ; Write access
CINH
PLC STOP
No transfer
COM
MOT
1 Acivate brake when n
1 active
1 Inverted