C00786, C00787, C00788 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 602: C00789, C00790, C00791, 9400 highline | parameter setting & configuration

9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00786
602
Firmware 1.37 - 09/2006
L
C00786
C00787
C00788
C00789
C00790
C00791
Parameter | Name:
C00786 | MCTRL_dnIxtLoad
Data type: INTEGER_32
Index: 23789
d
= 5CED
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-200.00
%
200.00
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00787 | MCTRL_dnFlyingSpeedAct
Data type: INTEGER_32
Index: 23788
d
= 5CEC
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-480000
rpm
480000
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00788 | MCTRL_dwMaxEffMotorTorque
Data type: INTEGER_32
Index: 23787
d
= 5CEB
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
0.000
Nm
2147483.647
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000
Parameter | Name:
C00789 | MCTRL_dwMaxDeviceCurrent
Data type: INTEGER_32
Index: 23786
d
= 5CEA
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
0.00
A
21474836.47
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00790 | MCTRL_dnI2xtLoad
Data type: INTEGER_32
Index: 23785
d
= 5CE9
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-200.00
%
200.00
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00791 | MCTRL_dnDeltaMotorPos_p
Data type: INTEGER_32
Index: 23784
d
= 5CE8
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-2147483647
Incr.
2147483647
;
Read access Write access CINH PLC STOP No transfer COM MOT