C00610, C00611, C00612 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 594: C00612/1, C00612/2, C00612/3, C00612/4, C00612/5, C00612/6, C00612/7

9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00610
594
Firmware 1.37 - 09/2006
L
C00610
C00611
C00612
Parameter | Name:
C00610 | Resp. to heatsink fan failure
Data type: UNSIGNED_32
Index: 23965
d
= 5D9D
h
Response if fan speed of heatsink fan is too low.
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
5 Warning
;
Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00611 | Resp. to integral fan failure
Data type: UNSIGNED_32
Index: 23964
d
= 5D9C
h
Response if fan speed of interior fan is too low.
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
5 Warning
;
Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00612 | Resp. to CAN node guarding error
Data type: UNSIGNED_8
Index: 23963
d
= 5D9B
h
Response of master, if the corresponding node guarding response is not received.
Selection list
0 No response
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
Subcodes
Lenze setting
Information
C00612/1
0: No response
Response to non received telegram for monitoring entry
1 ... 32
C00612/...
C00612/32
;
Read access ; Write access CINH PLC STOP No transfer COM MOT