9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Electronic gearbox" | Selection of master value source and output
12.2.4
Selection of master value source and output
[12-11] Signal flow for selecting the master value source and the master values to be output
Master value source
The master values can be either selected by a "Virtual master", via a bus system or the
digital frequency extension module.
Transmission of the master angle
r
They can be selected on the Application parameter tab via the Master value source list
field or via C03052.
Master value output
The master value to be output ( ... ) is selected individually for the three possible
communication channels:
r
List field Master value output DF module (C03197):
Selection of the master value output for the digital frequency module.
r
List field Master value output MotionBus (C03054/1):
Selection of the master value output for horizontal communication.
r
List field Master value output LPort32Out1 (C03054/2):
Selection of the master value output for vertical communication.
Master value with stretch factor with clutch with trimming Actual value
v
t
Dj
3
M
0
2
4
j
v
t
Virtual master
LPortAxisIn1
LPortAxisOut1
C03054/2
C03197
C03054/1
C03052
LPort32Out1
1