9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00393
582
Firmware 1.37 - 09/2006
L
C00393
C00395
C00396
C00397
C00398
C00399
Parameter | Name:
C00393 | CAN result - bus scan
Data type: UNSIGNED_8
Index: 24182
d
= 5E76
h
Result of CAN bus scanning (see controller commands under
• Subcode number 1 ... 128 corresponds to CAN node address 1 ... 128.
Display range
(min. value | unit | max. value)
0
1
Subcodes
Information
C00393/1
Result of CAN bus scanning for CAN node address 1 ...
128
• The value "1" means that a device with the
corresponding node address has been found.
C00393/...
C00393/128
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00395 | Service code
Data type: UNSIGNED_32
Index: 24180
d
= 5E74
h
This code is used internally by the controller and must not be overwritten by the user!
Parameter | Name:
C00396 | Service code
Data type: UNSIGNED_32
Index: 24179
d
= 5E73
h
This code is used internally by the controller and must not be overwritten by the user!
Parameter | Name:
C00397 | Service code
Data type: UNSIGNED_32
Index: 24178
d
= 5E72
h
This code is used internally by the controller and must not be overwritten by the user!
Parameter | Name:
C00398 | Test mode - motor control
Data type: UNSIGNED_32
Index: 24177
d
= 5E71
h
Selection list
(Lenze setting printed in bold)
0 Test mode deactivated
1 U rotation test mode
2 I rotation test mode
3 Current controller optimisation
mode
;
Read access ; Write access ; CINH PLC STOP ; No transfer COM MOT
Parameter | Name:
C00399 | Settings for test mode
Data type: INTEGER_32
Index: 24176
d
= 5E70
h
Setting range
(min. value | unit | max. value)
-1000.0
Hz/1°
1000.0
Subcodes
Lenze setting
Information
C00399/1
0.0 Hz/1°
Frequency [Hz] for test mode
C00399/2
0.0 Hz/1°
Start angle [°] for test mode
;
Read access ; Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 10