491
9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
CAN on board SDO server: Faulty configuration [0x00880000]
CAN on board SDO client: Faulty configuration [0x00890000]
ProjectSelection.dat file faulty [0x008c0000]
ProjectList.dat file faulty [0x008c0001]
DeviceCFG.dat file faulty [0x008c0002]
ProjectSelection.dat missing [0x008c0003]
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble : Warning locked Warning Information
Cause
Remedy
CAN on board: A configuration error has occurred in the
CAN SDO server.
• Faulty project download.
• Invalid SDO server settings according to DS301V402
in the Engineer or PLC Designer.
• Repeat download.
• Correct CAN settings in the project and regenerate
project.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble : Warning locked Warning Information
Cause
Remedy
CAN on board: A configuration error has occurred in the
CAN SDO client.
• Faulty project download.
• Invalid SDO client settings according to DS301V402 in
the Engineer or PLC Designer.
• Repeat download
• Correct CAN settings in the project and regenerate
project.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Internal error
Reformat memory module (
project download.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Internal error
Reformat memory module (
project download.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Internal error
Reformat memory module (
project download.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Internal error
Reformat memory module (
project download.