10 quick stop, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 319
L
Firmware 1.37 - 09/2006
319
9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Electronic gearbox" | Quick stop
12.2.10
Quick stop
[12-20] Basic function "Quick stop" (schematic diagram)
r
The quick stop function can be activated as follows in the Lenze setting:
– By setting the digital input DI1 to LOW level.
– By a master control via the port LPortControl1:
By setting bit 2 of the bit-coded control word 1.
r
Parameter setting: Tab Application parameter Dialog level Overview All basic
functions Quick stop
O
Tip!
Detailed information on quick stop can be found in chapter "Basic drive functions"
subchapter "
The basic function "Quick stop" brakes the
drive to standstill within the deceleration
time set for the quick stop function after a
corresponding request independent of the
setpoint selection.
If the quick stop function is deactivated,
the drive is led to the selected setpoint
again via the set acceleration time.
v
t
t
M
Slave
n
t
LS_Limiter
n
t
LS_Quickstop
STOP
Parameters
Lenze setting
Value Unit
Quick stop deceleration time
0.000 s
Quick stop S-ramp time
0.00 %
Reference for deceleration time "Quick stop"
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
DigIn 1 Activate quick stop 1
C03135/1
Control word 1
bit 02
Activate quick stop 2
C03135/2
FALSE Activate quick stop 3
C03135/3