Page 124: I/o terminals digital inputs, Control

9400 HighLine | Parameter setting & configuration
I/O terminals
Digital inputs
124
Firmware 1.37 - 09/2006
L
7.4.3
System block "LS_DigitalInput"
The system block LS_DigitalInput displays the digital inputs and the status of the state bus
in the function block editor.
Output
DIS code | data type
Value/meaning
DIGIN_bCInh
| BOOL
Status signal "Controller inhibit"
• An inverter is used to connect control input RFR (X5/pin 9) for the setting/reset of
controller inhibit to the device control (DCTRL).
TRUE Controller inhibit active
DIGIN_bIn1
| BOOL
...
DIGIN_bIn8
| BOOL
Digital inputs 1 ... 8
DIGIN_bStateBusIn
| BOOL
State bus status
Monitoring function "State bus" (C 127)
TRUE A device connected to the state bus has set the state bus to LOW
level and the status "Error" has been set.
• Status "Error" is also set if a device connected to the state bus is
not supplied with voltage.
LS_DigitalInput
DIGIN_bIn1
DIGIN_bIn2
DIGIN_bIn5
DIGIN_bIn4
DIGIN_bIn3
X5
DIGIN_bIn6
DIGIN_bIn7
DIGIN_bIn8
DIGIN_bCInh
DIGIN_bStateBusIn