9400 highline | parameter setting & configuration, Motor interface system block "ls_motorinterface – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 106
![background image](/manuals/566320/106/background.png)
9400 HighLine | Parameter setting & configuration
Motor interface
System block "LS_MotorInterface"
106
Firmware 1.37 - 09/2006
L
MI_bSpeedSetPointLimited
| BOOL
Status signal "Resulting speed setpoint in the limitation"
Signal flow - position follower (C 184)
Signal flow - speed follower (C 191)
TRUE The resulting speed setpoint is limited to the limit values
parameterised in
and
.
MI_dnSpeedSetpoint_n
DINT
Current speed setpoint from position control and speed feedforward control or
direct setpoint selection in [%]
• After limitation by the upper speed limit value (
) and lower speed limit
value (
• 100 % ≡ Motor reference speed (
Signal flow - position follower (C 184)
Signal flow - speed follower (C 191)
MI_dnSpeedSetpoint_s
DINT
Current speed setpoint from position control and speed feedforward control or
direct setpoint selection in [rpm]
• After limitation by the upper speed limit value (
) and lower speed limit
value (
MI_bSpeedFollowingError
| BOOL
Status signal "Impermissible speed control deviation"
Signal flow - speed follower (C 191)
TRUE Speed control deviation is higher than the window set in
.
MI_bSpeedCtrlLimited
| BOOL
Status signal "Speed controller in the limitation"
Signal flow - speed follower (C 191)
Signal flow - position follower (C 184)
TRUE The speed controller limitation is active.
MI_bTorqueSetpointLimited
| BOOL
Status signal "Total torque setpoint in the limitation"
Signal flow - motor interface (C 95)
TRUE The total torque setpoint is limited.
MI_dnTorqueSetpoint_n
DINT
Current torque setpoint from speed control and torque feedforward control or direct
setpoint selection
• After limitation by MI_dnTorqueLimit_n.
• 100 % ≡
Signal flow - motor interface (C 95)
MI_-
dnFilteredTorqueSetpoint_n
DINT
Filtered torque setpoint (after jerk limitation and band-stop filter)
• 100 % ≡
Signal flow - motor interface (C 95)
MI_bCurrentSetpointLimited
| BOOL
Status signal "Setpoint for current controller in the limitation"
Signal flow - motor interface (C 95)
TRUE The setpoint for the current controller is limited to I
max_device
MI_-
bMotorOverloadWarning
| BOOL
Status signal "Motor overload"
• Group signal for warning signals from temperature monitoring (KTY, PTC,
thermal switch) or I
2
xt monitoring.
TRUE One of the monitoring modes for motor overload protection is
active.
MI_-
bSpeedBelowThresholdC19
| BOOL
Status signal "Standstill reached"
TRUE The current speed is below the threshold set in
MI_-
dnActualMotorCurrent_n
DINT
Current motor current
• 100 % ≡ I
max_device
(
• Display in
Signal flow - motor interface (C 95)
MI_-
dnActualMotorVoltage_n
DINT
Current motor voltage
• 100 % ≡ 1000 V
• Display in
in [V]
Signal flow - motor interface (C 95)
Output
DIS code | Data type
Value/meaning