C02574, C02575, C02576 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 624: C02577, C02578, C02579, C02579/1, C02579/2, C02579/3, 9400 highline | parameter setting & configuration
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C02574
624
Firmware 1.37 - 09/2006
L
C02574
C02575
C02576
C02577
C02578
C02579
Parameter | Name:
C02574 | Actual speed
Data type: INTEGER_32
Index: 22001
d
= 55F1
h
Display range
(min. value | unit | max. value)
-214748.3647
Unit/s
214748.3647
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C02575 | Actual position
Data type: INTEGER_32
Index: 22000
d
= 55F0
h
Display range
(min. value | unit | max. value)
-214748.3647
Unit
214748.3647
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C02576 | Following error
Data type: INTEGER_32
Index: 21999
d
= 55EF
h
Display range
(min. value | unit | max. value)
-214748.3647
Unit
214748.3647
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C02577 | External actual position
Data type: INTEGER_32
Index: 21998
d
= 55EE
h
Display range
(min. value | unit | max. value)
-214748.3647
Unit
214748.3647
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C02578 | Offset actual pos. value/setp.
Data type: INTEGER_32
Index: 21997
d
= 55ED
h
Display range
(min. value | unit | max. value)
-214748.3647
Unit
214748.3647
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C02579 | Encoder eval.: Dig. signals
Data type: UNSIGNED_32
Index: 21996
d
= 55EC
h
Display of the boolean signals of the
(LS_Feedback).
Selection list
0 FALSE
1 TRUE
Subcodes
Information
C02579/1
FDB_bResolverError
C02579/2
FDB_bSinCosSignalError
C02579/3
FDB_bEncoderComError
;
Read access Write access CINH PLC STOP No transfer COM MOT