Parameter list | C01191
C01191
C01192
C01193
C01194
C01195
Parameter | Name:
C01191 | Temperature for spec. characteristic
Data type: UNSIGNED_32
Index: 23384
d
= 5B58
h
The special thermal sensor characteristic is selected by setting
Setting range
(min. value | unit | max. value)
0
°C
255
Subcodes
Lenze setting
Information
C01191/1
25 °C
Value 1 for spec. thermal sensor characteristic
C01191/2
150 °C
Value 2 for spec. thermal sensor characteristic
;
Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C01192 | Resistor for spec. characteristic
Data type: UNSIGNED_32
Index: 23383
d
= 5B57
h
The special thermal sensor characteristic is selected by setting
Setting range
(min. value | unit | max. value)
0
Ohm
30000
Subcodes
Lenze setting
Information
C01192/1
1000 Ohm
Value 1 for spec. thermal sensor characteristic
C01192/2
2225 Ohm
Value 2 for spec. thermal sensor characteristic
;
Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C01193 | Motor temp. feedback system
Data type: UNSIGNED_16
Index: 23382
d
= 5B56
h
Selection of feedback system for motor temperature detection.
Selection list
(Lenze setting printed in bold)
0 Speed feedback
1 Resolver X7
2 Encoder X8
3 Encoder module in MXI1
4 Encoder module in MXI2
;
Read access ; Write access ; CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C01194 | Motor operating temperature
Data type: INTEGER_32
Index: 23381
d
= 5B55
h
Setting range
(min. value | unit | max. value)
Lenze setting
1
°C
200 140 °C
;
Read access ; Write access CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C01195 | Influence winding I²xt mon.
Data type: UNSIGNED_32
Index: 23380
d
= 5B54
h
I
2
xt motor monitoring: Influence of the winding temperature
• By setting "0 %" the time constant for the winding is not considered and the thermal model is only calculated
with the time constant set for the housing/steel plates.
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
100 0 %
;
Read access ; Write access CINH PLC STOP No transfer COM ; MOT