Basic drive functions
Brake control | Mode 2/12: Automatic control of the brake
226
Firmware 1.37 - 09/2006
L
9.11.4.3
Process when brake is closed
The following process occurs if the enable of the requested basic function for traversing
the drive is deactivated again:
1. The drive is braked to standstill via the basic function "
basic function "
2. When speed setpoint and actual speed value have fallen below the speed threshold set
in
:
– The output BRK_bReleaseBrakeOut is set to FALSE for opening the brake.
– The current torque is saved to be used for the feedforward control for the next start,
if required.
– Monitoring of the brake module is deactivated temporarily.
– Monitoring of the status input is deactivated temporarily (if switched active via
– The lapse of brake closing time starts.
3. After the brake closing time has elapsed and the corresponding status change of the
status signal:
– The output BRK_bBrakeReleased is reset to FALSE.
– The controller inhibit is activated.
4. After the additional waiting time set for the status monitoring in
has elapsed:
– Monitoring of the brake module is active again.
– Monitoring of the status input is active again (if switched active via
– Standstill monitoring is activated.