13 signal configuration of the output ports, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 364
9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Synchronism with mark synchronisation" | Signal configuration of the output ports
364
Firmware 1.37 - 09/2006
L
12.3.13
Signal configuration of the output ports
If required, the preset signal configuration of the output ports can be easily reconfigured
per parameter setting of the assigned multiplexer parameters.
"LPortAxisOut1" output port
The output port LPortAxisOut1 is intended for the connection with a following axis.
Signal (Lenze setting)
Output port
Signal configuration
Axis status word
• Application-specific signals can be supplemented.
FALSE Axis status word bit 00
C03120/1
FALSE Axis status word bit 01
C03120/2
FALSE Axis status word bit 02
C03120/3
FALSE Axis status word bit 03
C03120/4
FALSE Axis status word bit 04
C03120/5
FALSE Axis status word bit 05
C03120/6
FALSE Axis status word bit 06
C03120/7
FALSE Axis status word bit 07
C03120/8
FALSE Axis status word bit 08
C03120/9
FALSE Axis status word bit 09
C03120/10
FALSE Axis status word bit 10
C03120/11
FALSE Axis status word bit 11
C03120/12
FALSE Axis status word bit 12
C03120/13
FALSE Axis status word bit 13
C03120/14
FALSE Axis status word bit 14
C03120/15
FALSE Axis status word bit 15
C03120/16
Setpoints for horizontal communication
0 % Axis-Port Out 1
C03124/1
Master value Axis-Port Out 2
C03054/1