Parameter list | C00779
C00779
C00780
C00781
C00782
C00783
C00784
Parameter | Name:
C00779 | MCTRL_dnDCBusVoltage
Data type: INTEGER_32
Index: 23796
d
= 5CF4
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
0
V
1000
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00780 | MCTRL_dnImotAct
Data type: INTEGER_32
Index: 23795
d
= 5CF3
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-500.00
A
500.00
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00781 | MCTRL_dwMaxMotorSpeed
Data type: UNSIGNED_32
Index: 23794
d
= 5CF2
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
0
rpm
480000
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00782 | MCTRL_dwMaxMotorTorque
Data type: UNSIGNED_32
Index: 23793
d
= 5CF1
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
0.000
Nm
2147483.647
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000
Parameter | Name:
C00783 | MCTRL_dwMotorVoltageAct
Data type: UNSIGNED_32
Index: 23792
d
= 5CF0
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
0
V
2000
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00784 | MCTRL_dnMotorFreqAct
Data type: INTEGER_32
Index: 23791
d
= 5CEF
h
Internal motor control (MCTRL) signal
Display range
(min. value | unit | max. value)
-800.0
Hz
800.0
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10