Commissioning using the »Engineer«
10.2
Commissioning using the »Engineer«
Basic procedure
1. Start »Engineer«.
2. Open available project or create a new project.
3. Assign each controller to a technology application from the catalogue.
4. For a project with several interconnected devices:
– Insert network and machine application .
– Make suitable network settings.
– Specialise the predefined ports to concrete interfaces for the devices involved in the
network on the Ports tab.
– Interconnect the ports conveniently inside the machine application.
5. Parameterise the application(s).
6.
Update devices.
7.
Go online.
8.
Download application(s) into the controller(s).
9. Confirm Dialog box Start application with Yes, all devices.
10. Confirm Dialog box Enable controller with Yes, all devices.
11. Control application(s) via terminals or network.
Note!
The downloaded application is basically stored in the first application memory
location of the controller.