13 application error messages, Application error messages, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 286
9400 HighLine | Parameter setting & configuration
Standard TAs
TA "Actuator – torque" | Application error messages
286
Firmware 1.37 - 09/2006
L
11.3.13
Application error messages
For the output of application-specific error messages an FB instance ApplicationError of the
function block L_DevApplErr is available in the network.
r
Via the 8 boolean inputs up to 8 different application error messages with
parameterisable module ID, error ID and error response can be released by the
application.
r
Parameter setting: Tab All parameters
Reset of error message
In the Lenze setting the digital input DI5 for resetting (acknowledging) an error message is
connected to the input DI_bResetError1 of the drive interface.
Error message
Error-ID
Error response
1
Torque follower in limitation
8001
Warning locked
2
-
8000
Error
3
-
8000
Error
4
-
8000
Error
5
-
8000
Error
6
-
8000
Error
7
-
8000
Error
8
-
8000
Error
Parameters
Lenze setting
C05900
Module-ID
980
C05901/1...8
Error ID 1 ... 8
See table above
C05902/1...8
Error response 1 ... 8
See table above