Wrong safety module [0x00680013, Power section has been changed [0x00680014, Mxi1: module has been changed [0x00680015 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 453: Mxi2: module has been changed [0x00680016, Memory module has been changed [0x00680017, Safety module has been changed [0x00680018, 9400 highline | parameter setting & configuration

L
Firmware 1.37 - 09/2006
453
9400 HighLine | Parameter setting & configuration
Diagnostics & error analysis
Error messages of the operating system
Wrong safety module [0x00680013]
Power section has been changed [0x00680014]
MXI1: Module has been changed [0x00680015]
MXI2: Module has been changed [0x00680016]
Memory module has been changed [0x00680017]
Safety module has been changed [0x00680018]
Response (Lenze setting printed in bold)
None : System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The safety module is not supported by the operating
system.
• Use a different module.
• Please contact Lenze.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble : Warning locked Warning : Information
Cause
Remedy
"The power section has changed since the last mains
switching."
- (Only information or warning locked if the hardware
type has changed as well)
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble : Warning locked Warning : Information
Cause
Remedy
"The extension module in the module receptacle MXI1
has changed since the last mains switching."
- (Only information or warning locked if the hardware
type has changed as well)
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble : Warning locked Warning : Information
Cause
Remedy
"The extension module in the module receptacle MXI2
has changed since the last mains switching."
- (Only information or warning locked if the hardware
type has changed as well)
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble : Warning locked Warning : Information
Cause
Remedy
"The memory module has changed since the last mains
switching."
- (Only information or warning locked if the hardware
type has changed as well)
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble : Warning locked Warning : Information
Cause
Remedy
"The safety module has changed since the last mains
switching."
- (Only information or warning locked if the hardware
type has changed as well)