Error messages of the operating system
Project is not available [0x008c000a]
Required license missing [0x008c000b]
MXI1: Module missing or incompatible [0x008c000d]
MXI2: Module missing or incompatible [0x008c000e]
MXI1: PROFIBUS module missing or incompatible [0x008c000f]
MXI2: PROFIBUS module missing or incompatible [0x008c0010]
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Application not available.
• Download application with the Engineer
• Switch off controller and use a different memory
module with an existing application.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Memory module could not be initialised.
Two possibilities:
• Use the Engineer to download and activate an
application suitable for the memory module.
• Switch off controller and use memory module
suitable for the application.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The extension module in module receptacle MXI1 is
incompatible with the application.
Use extension module supported by the application.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The extension module in module receptacle MXI2 is
incompatible with the application.
Use extension module supported by the application.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The communication module E94AYCPM (PROFIBUS) in
module receptacle MXI1 is incompatible with the
application.
Use communication module supported by the
application.
Response (Lenze setting printed in bold)
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The communication module E94AYCPM (PROFIBUS) in
module receptacle MXI2 is incompatible with the
application.
Use communication module supported by the
application.