C02109, C02113, C02121 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 614: C02122, C02123, C02520, The gearbox factor on the motor side, 9400 highline | parameter setting & configuration

9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C02109
614
Firmware 1.37 - 09/2006
L
C02109
C02113
C02121
C02122
C02123
C02520
Parameter | Name:
C02109 | Program runtime
Data type: UNSIGNED_16
Index: 22466
d
= 57C2
h
Display range
(min. value | unit | max. value)
0
μs
65535
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02113 | Program name
Data type: VISIBLE_STRING
Index: 22462
d
= 57BE
h
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02121 | Runtime task 1
Data type: UNSIGNED_32
Index: 22454
d
= 57B6
h
Display range
(min. value | unit | max. value)
0
μs
3600000000
Subcodes
Information
C02121/1
Curr. runtime task 1
C02121/2
max. runtime task 1
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02122 | Runtime task 2
Data type: UNSIGNED_32
Index: 22453
d
= 57B5
h
Display range
(min. value | unit | max. value)
0
μs
3600000000
Subcodes
Information
C02122/1
Curr. runtime task 2
C02122/2
max. runtime task 2
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02123 | Runtime task 3
Data type: UNSIGNED_32
Index: 22452
d
= 57B4
h
Display range
(min. value | unit | max. value)
0
μs
3600000000
Subcodes
Information
C02123/1
Curr. runtime task 3
C02123/2
max. runtime task 3
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02520 | Gearbox fact. numer. motor
Data type: INTEGER_32
Index: 22055
d
= 5627
h
Setting range
(min. value | unit | max. value)
Lenze setting
1
2147483647 1
;