C00494, C00495, C00497 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 586: C00512, C00513, C00514, C00515, C00516, And converted, Activated in

9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00494
586
Firmware 1.37 - 09/2006
L
C00494
C00495
C00497
C00512
C00513
C00514
C00515
C00516
Parameter | Name:
C00494 | Motor standstill time constant
Data type: UNSIGNED_32
Index: 24081
d
= 5E11
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
100000 0 ms
;
Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00495 | Motor encoder
Data type: UNSIGNED_16
Index: 24080
d
= 5E10
h
Selection list
(Lenze setting printed in bold)
0 Resolver X7
1 Encoder X8
2 Encoder module in MXI1
3 Encoder module in MXI2
;
Read access ; Write access ; CINH PLC STOP No transfer COM ; MOT
Parameter | Name:
C00497 | Speed act. val. time const.
Data type: UNSIGNED_32
Index: 24078
d
= 5E0E
h
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
ms
50.0 2.0 ms
;
Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10
Parameter | Name:
C00512 | Service code
Data type: UNSIGNED_32
Index: 24063
d
= 5DFF
h
This code is used internally by the controller and must not be overwritten by the user!
Parameter | Name:
C00513 | Service code
Data type: VISIBLE_STRING
Index: 24062
d
= 5DFE
h
This code is used internally by the controller and must not be overwritten by the user!
Parameter | Name:
C00514 | Service code
Data type: UNSIGNED_32
Index: 24061
d
= 5DFD
h
This code is used internally by the controller and must not be overwritten by the user!
Parameter | Name:
C00515 | Service code
Data type: UNSIGNED_32
Index: 24060
d
= 5DFC
h
This code is used internally by the controller and must not be overwritten by the user!
Parameter | Name:
C00516 | Service code
Data type: UNSIGNED_32
Index: 24059
d
= 5DFB
h
This code is used internally by the controller and must not be overwritten by the user!