C02569, C02570, C02572 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 623: C02573, C02569/2, C02569/3, C02569/4, C02569/5, C02569/10, C02569/6

L
Firmware 1.37 - 09/2006
623
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C02569
C02569
C02570
C02572
C02573
Parameter | Name:
C02569 | Motor interface: Dig. signals
Data type: UNSIGNED_32
Index: 22006
d
= 55F6
h
Display of the boolean signals of the
(LS_MotorInterface).
Selection list
0 FALSE
1 TRUE
Subcodes
Information
C02569/1
Reserved
C02569/2
MI_bResetSpeedCtrlIntegrator
C02569/3
MI_bLimitationActive
C02569/4
MI_bPosCtrlLimited
C02569/5
MI_bSpeedSetPointLimited
C02569/6
MI_bSpeedCtrlLimited
C02569/7
MI_bTorqueSetpointLimited
C02569/8
MI_bCurrentSetpointLimited
C02569/9
MI_bSpeedBelowC19
C02569/10
MI_bSpeedFollowingError
C02569/11
MI_bMotorOverloadWarning
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02570 | Controller configuration
Data type: UNSIGNED_32
Index: 22005
d
= 55F5
h
Selection list
(Lenze setting printed in bold)
Information
1 Phase control
Motor encoder selection is effected in
2 Position control
Position controller selection is effected in
.
;
Read access ; Write access ; CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02572 | Speed setpoint
Data type: INTEGER_32
Index: 22003
d
= 55F3
h
Display range
(min. value | unit | max. value)
-214748.3647
Unit/s
214748.3647
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C02573 | Position setpoint
Data type: INTEGER_32
Index: 22002
d
= 55F2
h
Display range
(min. value | unit | max. value)
-214748.3647
Unit
214748.3647
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000