C00061, C00062, C00063 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 550: C00064, C00065, C00066, C00068, Displayed in, Indic, 9400 highline | parameter setting & configuration
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00061
550
Firmware 1.37 - 09/2006
L
C00061
C00062
C00063
C00064
C00065
C00066
C00068
Parameter | Name:
C00061 | Heatsink temperature
Data type: INTEGER_32
Index: 24514
d
= 5FC2
h
Display range
(min. value | unit | max. value)
-200
°C
200
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00062 | Temp. inside the controller
Data type: INTEGER_32
Index: 24513
d
= 5FC1
h
Display range
(min. value | unit | max. value)
-200
°C
200
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00063 | Motor temperature
Data type: INTEGER_32
Index: 24512
d
= 5FC0
h
Display range
(min. value | unit | max. value)
-200
°C
200
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00064 | Device utilisation (Ixt)
Data type: UNSIGNED_32
Index: 24511
d
= 5FBF
h
Controller load during the last 180 seconds
• C00064 > 100 % activates error (OC5).
• Error reset only possible if C00064 < 95 %.
Display range
(min. value | unit | max. value)
0
%
250
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00065 | Ext. 24-V voltage
Data type: INTEGER_32
Index: 24510
d
= 5FBE
h
Display range
(min. value | unit | max. value)
0.0
V
1000.0
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10
Parameter | Name:
C00066 | Thermal motor load (I²xt)
Data type: UNSIGNED_32
Index: 24509
d
= 5FBD
h
A 100 % load corresponds to a permanently flowing rated motor current
Display range
(min. value | unit | max. value)
0
%
250
;
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00068 | Capacitor temperature
Data type: INTEGER_32
Index: 24507
d
= 5FBB
h
Display range
(min. value | unit | max. value)
-200
°C
200
;