9400 HighLine | Parameter setting & configuration
Standard TAs
TA "Actuator – torque" | Speed limit value conditioning
276
Firmware 1.37 - 09/2006
L
Use of further ramp parameter sets
If required, 15 further ramp parameter sets can be parameterised. For the selection of the
ramp parameter sets1 ... 15 the selection inputs are to be assigned with the corresponding
signals. The selection of the ramp parameter sets is carried out in a binary coded manner.
r
Parameter setting: Tab Application parameter Dialog levelOverview Ramp
generator All ramp parameters
Parameters
Lenze setting
Value Unit
C03512/1
Acceleration time 1
0.000 s
C03512/...
Acceleration time ...
... ...
C03512/15
Acceleration time 15
0.000 s
C03513/1
Deceleration time 1
0.000 s
C03513/...
Deceleration time ...
... ...
C03513/15
Deceleration time 15
0.000 s
C03514/1
S-ramp time 1
0.000 s
C03514/...
S-ramp time
... ...
C03514/15
S-ramp time 15
0.000 s
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
FALSE Activate ramp parameter set 1
C03009/8
FALSE Activate ramp parameter set 2
C03009/9
FALSE Activate ramp parameter set 4
C03009/10
FALSE Activate ramp parameter set 8 a
C03009/11