15 application error messages, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 327
![background image](/manuals/566320/327/background.png)
L
Firmware 1.37 - 09/2006
327
9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Electronic gearbox" | Application error messages
12.2.15
Application error messages
For the output of application-specific error messages an FB instance ApplicationError of the
function block L_DevApplErr is available in the network.
r
Via the 8 boolean inputs up to 8 different application error messages with
parameterisable module ID, error ID and error response can be released by the
application.
r
The first four inputs can be connected to the multiplexer parameters with the desired
tripping signals. The next four inputs are firmly connected to the tripping signals of the
application.
r
Parameter setting: Tab All parameters
Error message
Error-ID
Error response
1
Free (configurable via C03060/1)
8001
No reaction
2
Free (configurable via C03060/2)
8002
Error
3
Free (configurable via C03060/3)
8003
Error
4
Free (configurable via C03060/4)
8004
Error
5
Following error
8005
Warning
6
Drive cannot follow
8006
Warning
7
Drive system interrupted
8007
Quick stop by trouble
8
External fault in drive system
8008
Quick stop by trouble
Parameters
Lenze setting
C03990
Module-ID
999
C03991/1...8
Error ID 1 ... 8
See table above
C03992/1...8
Error response 1 ... 8
See table above
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
FALSE Application fault 1
C03060/1
FALSE Application fault 2
C03060/2
FALSE Application fault 3
C03060/3
FALSE Application fault 4
C03060/4