4 master value trimming, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 349

L
Firmware 1.37 - 09/2006
349
9400 HighLine | Parameter setting & configuration
TAs for interconnection via electrical shaft
TA "Synchronism with mark synchronisation" | "Synchronism" mode"
12.3.5.4
Master value trimming
[12-30] "Master value trimming" function in the signal flow (schematic diagram)
This function serves to adjust the master value.
r
Parameter setting: Tab Application parameter Dialog level Overview Synchronism
Master value trimming
r
Configuration: Tab FB editor FB Trimming
n
Master value with clutch
o
Master value with trimming
M
v
Slave
Real master/
Virtual master
C03006 = 0
v
t
Dj
Dj
Dj
TP
TP
Parameters
Lenze setting
Value Unit
C03674
Master value with clutch
- Unit
C03026
Activate trimming
Deactivated
C03676
Adjustable range
0.0000 Unit/t
C03685
Positioning mode
0
C03686
Deactivation mode
1
C03688/1
Positive speed
1000.0000 Unit/t
C03688/2
Negative speed
1000.0000 Unit/t
C03691/1
Acceleration ramp
0.500 s
C03691/2
Deceleration ramp
0.500 s
C03691/3
Stop ramp
1.000 s
C03723
Master value with trimming
- Unit
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
FALSE Start trimming
C03058/15
C03026 Activate trimming
C03058/16
FALSE Set trimming setpoint to 0
C03058/17