C02708, C02709, C02710 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 640: C02711, C02708/1, C02709/1, C02710/1, C02711/1, C02708/2, C02710/2
![background image](/manuals/566320/640/background.png)
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C02708
640
Firmware 1.37 - 09/2006
L
C02708
C02709
C02710
C02711
Parameter | Name:
C02708 | Limited speed
Data type: INTEGER_32
Index: 21867
d
= 556B
h
Basic function "
Setting range
(min. value | unit | max. value)
0.0000
Unit/s
214748.3647
Subcodes
Lenze setting
Information
C02708/1
3600.0000 Unit/s
Limited speed 1 ... 4
C02708/2
7200.0000 Unit/s
C02708/3
14400.0000 Unit/s
C02708/4
28800.0000 Unit/s
;
Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C02709 | Limited speed
Data type: INTEGER_32
Index: 21866
d
= 556A
h
Basic function "
Display range
(min. value | unit | max. value)
0.0
rpm
214748364.7
Subcodes
Information
C02709/1
Limited speed 1 ... 4
C02709/2
C02709/3
C02709/4
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10
Parameter | Name:
C02710 | Delay lim. speed
Data type: UNSIGNED_32
Index: 21865
d
= 5569
h
Basic function "
Setting range
(min. value | unit | max. value)
0.0000
Unit/s²
214748.3647
Subcodes
Lenze setting
Information
C02710/1
0.0100 Unit/s²
Delays for limited speed 1 ... 4
C02710/2
0.0100 Unit/s²
C02710/3
0.0100 Unit/s²
C02710/4
0.0100 Unit/s²
;
Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C02711 | S-ramp time lim. speed
Data type: UNSIGNED_32
Index: 21864
d
= 5568
h
Basic function "
Setting range
(min. value | unit | max. value)
0
ms
10000
Subcodes
Lenze setting
Information
C02711/1
100 ms
S-ramp times for limited speed 1 ... 4
C02711/2
100 ms
C02711/3
100 ms
C02711/4
100 ms
;
Read access ; Write access CINH PLC STOP No transfer COM MOT