6 set rotor displacement angle, S motor, Set rotor displacement angle – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 71: C 71), Set rotor displacement angle (c 71)
L
Firmware 1.37 - 09/2006
71
9400 HighLine | Parameter setting & configuration
Motor interface
Initial commissioning | Set rotor displacement angle
5.1.6
Set rotor displacement angle
For the control of permanent-magnet synchronous machines, the rotor angle – the angle
between the motor phase U and the field axis of the rotor – must be known.
r
For Lenze motors the rotor displacement angle for different feedback systems is
already set correctly in
.
r
The device command "Set rotor displacement angle" serves to specify the rotor
displacement angle for the current motor encoder activated in
for an external
motor (see following instructions).
M
How to set the rotor displacement angle for an external motor:
1. If the controller is enabled, inhibit the controller, e.g. with the device command
= "41").
2. Execute device command "Set rotor displacement angle" with
The procedure starts with controller enable, if
• a synchronous machine is selected,
• no other identification is active,
• no error (TRIP) has occurred, and
• no test mode is activated.
If one of the above conditions is not met, the procedure is cancelled and the
corresponding controller command status is indicated under
Note:
By means of controller inhibit the started procedure can be aborted any time
without making a change in
.
For detailed information about the procedure, please see the following section
"Sequence".
O
Tip!
For controller enable all sources for controller inhibit must be reset. In
the
sources for controller inhibit are displayed in a bit-coded manner.
The status of the controller command activated under
is indicated under
Note!
Not required if a Lenze motor is operated on the controller!
Note!
During the procedure of setting the rotor displacement angle, the machine must
not be braked or blocked.