C00636, C00637, C00691 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 597: C00692, C00693, C00694, 9400 highline | parameter setting & configuration
L
Firmware 1.37 - 09/2006
597
9400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00636
C00636
C00637
C00691
C00692
C00693
C00694
Parameter | Name:
C00636 | Resp. to new module in MXI1
Data type: UNSIGNED_32
Index: 23939
d
= 5D83
h
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
;
Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00637 | Resp. to new module in MXI2
Data type: UNSIGNED_32
Index: 23938
d
= 5D82
h
Selection list
(Lenze setting printed in bold)
0 No response
1 Error
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
;
Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00691 | Total speed setpoint
Data type: INTEGER_32
Index: 23884
d
= 5D4C
h
Display range
(min. value | unit | max. value)
-200.00
%
200.00
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00692 | Speed setpoint
Data type: INTEGER_32
Index: 23883
d
= 5D4B
h
Display range
(min. value | unit | max. value)
-200.00
%
200.00
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00693 | Actual speed
Data type: INTEGER_32
Index: 23882
d
= 5D4A
h
Display range
(min. value | unit | max. value)
-200.00
%
200.00
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00694 | Speed controller output
Data type: INTEGER_32
Index: 23881
d
= 5D49
h
Display range
(min. value | unit | max. value)
-200.00
%
200.00
;
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100