3 basic settings, 1 machine parameters, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual
Page 375
![background image](/manuals/566320/375/background.png)
L
Firmware 1.37 - 09/2006
375
9400 HighLine | Parameter setting & configuration
TAs for positioning tasks
TA "Multi-purpose positioning" | Basic settings
13.2.3
Basic settings
13.2.3.1
Machine parameters
O
Tip!
In the »Engineer« the most important machine parameters can be adapted to the
machine on the Application parameter tab directly in the topmost Overview dialog
level:
Detailed information for selecting and entering the machine parameters can be
Short overview of machine parameters
The machine parameters describe e.g. the motor end of the mechanics
used.
The setting of the machine parameters in the »Engineer» is carried out on
the Application parameters tab in the dialog level Overview Machine
parameters.
Parameters
Lenze setting
Value Unit
Mains - voltage
400/415 V
Threshold undervoltage (LU)
285 V
Resp. to DC bus overvoltage
Trouble
Gearbox fact. numer. motor
1
Gearbox fact. denom. motor
1
Motor mounting direction
Motor rotating CW
Controller configuration
Phase control
Gearbox fact. numer. load
1
Gearbox fact. denom. load
1
Mounting direction of position encoder
Encoder rotating CW
Description of the mechanics (load, tool)
Traversing range
Unlimited
Feed constant
360.0000 Unit
Unit
°
User-defined unit
°
Time unit
s
Motor moment of inertia
Motor-dependent kg cm
2
Load moment of inertia
0.00 kg cm
2
M