beautypg.com

IAI America XSEL-S User Manual

Page 98

background image

Chapter 2 Wiring

2.2.7 PIO Circuit

90

(2) Output Port Allocation

Parameter

Port

No.

No.

Name

Set

Value

Function of an Input Signal

At the

Delivery

0

Universal output

1

Error Output at the Operation Cancellation Level or more (ON)�

2

Error Output at the Operation Cancellation Level or more (OFF)�

3

Error Output at the Operation Cancellation Level or more +

Emergency-stop output (ON)

4

Error Output at the Operation Cancellation Level or more +

Emergency-stop output (OFF)

5

Output of an error higher than cold level (ON)

6

Output of an error higher than cold level (OFF)

7

Output of an error of maintenance information alert function related

message level (Error No. 231 or 232) (ON)

300

No.46

Output

Function

Select 300

8

Output of an error of maintenance information alert function related

message level (Error No. 231 or 232) (OFF)

0

Universal output

READY Output (PIO Trigger Program Operation Available)

2

READY Output (PIO Trigger Program Operation Available) and without

occurrence of any error at the operation cancellation level or more

301

No.47

Output

Function

Select 301

3

READY Output (PIO Trigger Program Operation Available, and

without occurrence of any error at the cold start level or more)

0

Universal output

1

Emergency-stop output(ON)

302

No.48

Output

Function

Select 302

2

Emergency-stop output(OFF)

0

Universal output

1

AUTO Mode Output

303

No.49

Output

Function

Select 303

2

Output during the Automatic Operation (In addition, when the

parameter No. 12

0

Universal output

1

Output at the time of “All Effective Axes Homing (=0)”

However, the SCALA robot is unavailable.

2

Output when all the effective axes homing is completed

(Coordinates Not Determined) However, the SCALA robot is unavailable.

304

No.50

Output

Function

Select 304

3

Output when all the effective axes home preset coordinates are

setHowever, the SCALA robot is unavailable.

0

Universal output

1

1

st

axis in-position output (turned OFF when pressing missed)

305

No.51

Output

Function

Select 305

2

Output during the first axis servo ON (System Monitoring Task Output)

0

Universal output

1

2

nd

axis in-position output (turned OFF when pressing missed)

306

No.52

Output

Function

Select 306

2

Output during the second axis servo (System Monitoring Task Output)

0

Universal output

1

3

rd

axis in-position output (turned OFF when pressing missed)

307

No.53

Output

Function

Select 307

2

Output during the third axis servo (System Monitoring Task Output)

0

Universal output

1

4

th

axis in-position output (turned OFF when pressing missed)

308

No.54

Output

Function

Select 308

2

Output during the fourth axis servo (System Monitoring Task Output)

0

Universal output

1

5

th

axis in-position output (turned OFF when pressing missed)

309

No.55

Output

Function

Select 309

2

Output during the fifth axis servo (System Monitoring Task Output)

0

Universal output

1

6

th

axis in-position output (turned OFF when pressing missed)

310

No.56

Output

Function

Select 310

2

Output during the sixth axis servo (System Monitoring Task Output)

0

Universal output

1

7

th

axis in-position output (turned OFF when pressing missed)

311

No.57

Output

Function

Select 311

2

Output during the seventh axis servo (System Monitoring Task Output)

0

Universal output

1

8

th

axis in-position output (turned OFF when pressing missed)

312

No.58

Output

Function

Select 312

2

Output during the eight axis servo (System Monitoring Task Output)

313

No.59

Output

Function

Select 313

0

Universal output

0

Universal output

314

No.60

Output

Function

Select 314

Absolute Battery Backup Battery Low Voltage Alarm Level or lessAll

axes OR check: After the abnormal level has been detected, it is

latched until Power ON reset and software reset.

315

No.61

Output

Function

Select 315

0

Universal output

This manual is related to the following products: