IAI America XSEL-S User Manual
Page 319
Chapter 6 Parameter
6.1 I/O Parameter (All types)
311
I/O Parameter (All types)
No.
Parameter name
Default
value
(reference)
Input
range
Unit
Remarks
428 Reserved by the system
(change is prohibited)
0H
429 Reserved by the system
(change is prohibited)
0H
430 Reserved by the system
(change is prohibited)
4000
431 Fieldbus Master Function
Select
0H
0H to
FFFFFFFFH
Bits 0 to 3: Function Select
(0: Disable, 1: RC Gateway)
Bits 4 to 7: Offline slave data process select
(0: Clear, 1: Hold (most recent normal
retain))
432 Fieldbus Slave 0 Construction
Definition
0H
0H to
FFFFFFFFH
Bits 0 to 7: Connected controller type
(0: Not connected,
1: MSEP
2: ACON/PCON, PCON-CA
3: SCON-CA)
4: MSCON
Bits 8 to 15: Slave input size (byte)
Bits 16 to 23: Slave output size (byte)
433 Fieldbus Slave 1 Construction
Definition
0H
0H to
FFFFFFFFH
(Same as I/O parameter No. 432)
434 Fieldbus Slave 2 Construction
Definition
0H
0H to
FFFFFFFFH
(Same as I/O parameter No. 432)
435 Fieldbus Slave 3 Construction
Definition
0H
0H to
FFFFFFFFH
(Same as I/O parameter No. 432)
436 Fieldbus Slave 4 Construction
Definition
0H
0H to
FFFFFFFFH
(Same as I/O parameter No. 432)
437 Fieldbus Slave 5 Construction
Definition
0H
0H to
FFFFFFFFH
(Same as I/O parameter No. 432)
438 Fieldbus Slave 6 Construction
Definition
0H
0H to
FFFFFFFFH
(Same as I/O parameter No. 432)
439 Fieldbus Slave 7 Construction
Definition
0H
0H to
FFFFFFFFH
(Same as I/O parameter No. 432)
440 Fieldbus Slave 8 Construction
Definition
0H
0H to
FFFFFFFFH
(Same as I/O parameter No. 432)
441 Fieldbus Slave 9 Construction
Definition
0H
0H to
FFFFFFFFH
(Same as I/O parameter No. 432)
442 Fieldbus Slave 10 Construction
Definition
0H
0H to
FFFFFFFFH
(Same as I/O parameter No. 432)
443 Fieldbus Slave 11 Construction
Definition
0H
0H to
FFFFFFFFH
(Same as I/O parameter No. 432)
444 Fieldbus Slave 12 Construction
Definition
0H
0H to
FFFFFFFFH
(Same as I/O parameter No. 432)
445 Fieldbus Slave 13 Construction
Definition
0H
0H to
FFFFFFFFH
(Same as I/O parameter No. 432)
446 Fieldbus Slave 14 Construction
Definition
0H
0H to
FFFFFFFFH
(Same as I/O parameter No. 432)
447 Fieldbus Slave 15 Construction
Definition
0H
0H to
FFFFFFFFH
(Same as I/O parameter No. 432)
448 Fieldbus Configuration Attribute
1
4BH
0H to
FFFFFFFFH
Bits 0 to 12: EPR (Expected Packet Rate)
Bits 13 to 31: ISD (Interscan Delay)
*Perform the setting to make ISD*3 < EPR.
449 (For expansion)
0
450 (For expansion)
0
451 (For expansion)
0
452 (For expansion)
0
453 (For expansion)
0
454 (For expansion)
0
455 (For expansion)
0
456 (For expansion)
0
457 (For expansion)
0
458 (For expansion)
0
459 (For expansion)
0