beautypg.com

IAI America XSEL-S User Manual

Page 445

background image

Chapter 7

Troubleshooting

7.3 Error List (MAIN application)

437

In the panel window, the error numbers follow E in the display.

Error

No.

Error name

Description, action, etc.

81B Mounted-SIO parity ER status (SEL

reception)

Communication failure.

Check for noise, shorted/disconnected communication

cable, connected equipment and communication setting.

81C Mounted-SIO framing ER status

(SEL reception)

Communication failure.

Check for noise, shorted/disconnected communication

cable, connected equipment and communication setting.

81D Mounted-SIO S-receive queue

overflow status (SEL reception)

The receive queue in the mounted-SIO CPU overflowed.

Excessive data was received from outside.

81E Mounted-SIO M-receive temporary

queue overflow status (SEL

reception)

The temporary receive queue in the main CPU overflowed.

Excessive data was received from outside.

81F Mounted-SIO M-receive buffer

overflow status (SEL reception)

The receive buffer overflowed.

Excessive data was received from outside.

820 DRV status 820

(TO_SELECTEDDATA)

(This is not an error, but maintenance information.)

821 Tracking system adjustment

classification indication error

The tracking system adjustment classification indication is

not appropriate Indicate only the allowable classification

type.

*It is an error only for SCARA

822 RC-gateway modbus

communication retry status

Modbus communication was retried. (This is not an error.)

823 Power-off status during slave data

flash ROM writing

The power was turned off while in the process of the data

flash ROM writing on a slave board on such as the

extension motion control board.

824 Controller power-on Log

This is the log for the controller power-on clock.

(This is not an error.)

S

ec

re

t l

ev

el

e

rr

or

s

825 Controller software reset Log

This is the log for the controller software reset clock. (This

is not an error.)